Product

Electric vacuum drying oven laboratory

Short Description:


  • Voltage(V): 220V
  • Power (W): 1300
  • Range of temperature(℃): 50-250
  • Wave degree of temperature(℃): Wave degree of temperature(℃)
  • Wave degree of temperature(℃): Wave degree of temperature(℃)
  • Number of shelves: 2
  • Product Detail

    Product Tags

    vacuum drying oven with vacuum pump

     

    1.Uses
    This product is suitable for industrial enterprises, universities, research institutes and other laboratory items drying and heat treatment under vacuum. Vacuum heat of the items in a vacuum oven, vacuum drying oven has the following advantages: (1) to reduce the drying temperature, shorten the drying time. (2) to avoid some of the items in the heating and oxidation under routine conditions, dust particles, destruction and the heated air to kill biological cells.
    2.The structural features
    The shape of the vacuum oven is a horizontal type.The chamber is made of high quality steel with stamping and welding.The surface is with coating processing. Insulation layer is filled with silicate cotton; The door is with double tempering glass door.The tightness of the door is adjustable; using a modular high-temperature silicon rubber gasket between the workroom and the glass door to ensure the seal, substantially increased the vacuum degree. The DZF type is square workroom.

    3. installation and commissioning
    1)Installation: vacuum drying oven should be placed in the indoors with good ventilation conditions, no strong vibration, can not be placed around inflammable, explosive and corrosive gases.
    2)Debug: Close the door and tighten the door handle.Close the back valve and open the vacuum valve. Connect the airway tube on the side way of the chamber with the vacuum pump by rubber tube.Open the vacuum pump power, start pumping. when the vacuum meter indicates the value ​​meeting the requirements,close the vacuum valve and vacuum pump power. Now the chamber is in the vacuum state. If there is no heating function,the debugging of the vacuum drying oven is end.

    4.the main technical data:

          Model          DZF-2
        VoltageV           220
        Power  (W)          1300
        Range of temperature(℃)          50-250
        Wave degree of temperature(℃)           ±1
        Workroom size(mm)       415x345x370
        Vacuum degreePa           133
        Number of shelves            2

    5.use
    1).Put the samples into the chamber,close the door and tighten the door handle. Close the back valve, open the vacuum valve, Connect the airway tube on the side way of the chamber with the vacuum pump by rubber tube.Open the vacuum pump power, start pumping.When the vacuum meter indicates the vacuum degree meeting your needs,close the vacuum valve, and then turn off the vacuum pump.Now the chamber is in the vacuum state.

    2), After the power is turned on, turn on the power switch,the indicator light is light,means working finely. The meter displays the workroom temperature, and then adjust the control meter to the setting temperature, the workroom begins heating. Green light on the control meter indicates that power-warming.When the instrument heats after 60 minutes, the displaying temperature should be basically the same with the setting temperature.

    3), the different samples and different temperatures, should select different drying time.If the drying time is long, the vacuum degree declines, need pump to restore the vacuum degree, should be turned on the vacuum pump first, and then open the vacuum valve.
    4), after drying, you should turn off the power, rotating the back valve, lift the vacuum state of the chamber, open the door to remove samples (the rubber ring attracts tightly with glass door after vacuum.It is difficult to open the door.After some time,it can be opened).

    5), control the temperature shall not be less than 50 ° C under vacuum condition. If less than 50 ℃, the values ​​of the standard thermometer is not match with the display the values,it is a normal phenomenon. This phenomenon does not affect the temperature control and temperature above 50 ℃.
    6), the indicator definition

     