1、 Summary This machine was used in department of environment protect、sanitary and antiepidemic、drug supervision、marine lives. It is the special equipment for Liquid test and culture、save the BOD test、Bacillus、Mold、Microorganism. Constructure Characteristic A .The case is adoptes high quality cold-rolled steel plate with the plastic spraying on the surface. B .Mirro-stainless working room, easy clean, Shelves can be adjusted. C .Micro-Computer Tem. Controller and Automatic defrosting system, can make sure the high precise and working continue, big LCD Screen. D. Sole Tem.limited alarm system、Over-Tem. cut off electric and timing function, can make sure the safety operate. E .R134A famous compressor and fans. F. Double doors, inner door is the good quality steel-glass, silicon seal, outside door is the magnetic silicon, easy open and close, make sure the good seal. G. ¢50mm big test hole, can test the chamber line、power and other condition. H. Optional function ①RS-485/232 connector, can contact with the computer ②Typer(minisize) ③Alarm system when electric cut off. ④Cut off electric or Alarm function when open the door ⑤Creepage protect The above Optional parts should be made by our company.2、Diagram Specification、Specification Diagram
Working Condition
① Environment Tem.: 5~32℃(if setting tem.≦10℃,environment ≦28℃). ② Humidity:≦80%RH ③ Air Pressor: 80-106Kpa ④ There was no shake of the incubator and not caustic air around the chamber. ⑤ Should avoid light and cooling environment. ⑥ Keep distance of the dust, isntall horizontal and make sure a distance between the equipment and wall. ⑦ Good airiness.
Safety Items 1 After you received the equipment, to avoid the damage for the compressor during a long transport, please keep the machine leave 1 days and then can use. To make sure equpment and test safety, please install the outer protect and also use the power as the equpment required.
2 Do not test the flammable and conmustible、poisonous and corrosive material.
3 The equipment should be installed horizontal.
4 Only the engineer can disassmebly and repair.
5 If put one working equipment into the chamber, once the power bigger than 2A, please add the power outside, please do not use this equipment power.
6 When the chamber tem.≧50℃, please do not setting the low tem. to avoid the compressor working, to make sure the compressor can be used long time.
7 Once alarm operate, please resolve this problem, please do not turn on the machine.
8 Please read this manual operation and then operat this machine.